Serving Las Vegas, Henderson, Summerlin, Boulder City(725) 900-0963
Model support

Maytag MGDB850WR Gas dryer

Troubleshooting, fault codes and repair information for the Maytag MGDB850WR, organized around the engineering platform this gas dryer is built on.

Brand
Maytag
Model
MGDB850WR
Engineering revisions
MGDB850WR0, MGDB850WR1
Appliance
Gas dryer
Platform
Gas dryer platform, documentation from about 2008
Models on this platform
22 across Maytag
Documented fault codes
14 with explanations
Service diagnostic mode
Yes — a console-only test mode used by technicians to read stored codes and run component tests
Service documentation
Tech sheet (used by our technicians; not published)

Maytag MGDB850WR error codes

These are the fault codes documented for the platform this model belongs to. A code describes a condition the control detected; it does not by itself identify a failed part. Select a code for causes, safe checks and repair context.

CodeMeaningAreas involved
F1E1Main control faultMain control board, Wiring harness and connectors, Drive motor
F2E2User interface software errorUser interface / keypad board, Wiring harness and connectors
F3E1Exhaust thermistor faultTemperature sensor (thermistor), Wiring harness and connectors, Main control board
F3E2Exhaust thermistor shortedTemperature sensor (thermistor), Wiring harness and connectors, Main control board
F3E3Inlet thermistor faultTemperature sensor (thermistor), Wiring harness and connectors, Main control board
F3E4Inlet thermistor shortedTemperature sensor (thermistor), Wiring harness and connectors, Main control board
F3E5Inlet and exhaust thermistors openWiring harness and connectors, Temperature sensor (thermistor), Main control board
F3E7Moisture sensor shortedMoisture sensor bars, Wiring harness and connectors
F4E1Heat circuit or connector problemHeating element, Gas valve and coils, Igniter
F4E3Restricted airflowExhaust vent duct, Blower wheel, Temperature sensor (thermistor)
F4E4L2 line voltage errorWiring harness and connectors, Main control board
F6E1Communication error (control and interface)Wiring harness and connectors, User interface / keypad board, Main control board
F6E2Communication error (control to interface)Wiring harness and connectors, User interface / keypad board, Main control board
PFPower failureWiring harness and connectors

Common dryer problems

Typical dryer repair costs

RepairTypical rangeLabor
Dryer thermal fuse and thermostat replacement$180–$310Light
Gas dryer valve coil or gas valve replacement$180–$420Moderate
Gas dryer igniter and flame sensor replacement$180–$370Light
Dryer drive motor or blower wheel replacement$250–$550Heavy
Dryer drum belt replacement$180–$320Light
Dryer drum rollers, glides and idler pulley replacement$190–$420Moderate
Dryer moisture sensor bar repair$180–$310Light
Dryer door switch replacement$180–$290Light
Dryer exhaust thermistor replacement$180–$290Light
Dryer main control board replacement$280–$640Moderate

Typical total ranges for the Las Vegas area, parts and labor included. The final cost depends on diagnosis, the exact model, parts availability and whether other damage is found.

Repair or replace?

Dryers typically last about 12–14 years. Service documentation for this platform dates from about 2008, so the oldest units built on it are now around 18 years old. The age printed in the serial number, the repair cost and the condition of the rest of the appliance decide it. Use the repair-or-replace guide.

These models share this platform's service documentation, so fault codes and most diagnostic steps are the same.

Need your Maytag MGDB850WR repaired in the Las Vegas area?

We repair Whirlpool, Maytag, KitchenAid, JennAir, Amana and other Whirlpool-family appliances in Las Vegas, Henderson, Summerlin and Boulder City. A model number helps but is never required to book.