Serving Las Vegas, Henderson, Summerlin, Boulder City(725) 900-0963
Error code

Roper dryer F02: keypad or user interface failure

F02 (F-02) means a control panel button appears stuck or the user interface does not match the control. It appears only in the diagnostic test mode.

What F02 means

Brand
Roper
Appliance
Gas dryer
Code
F02
Documented meaning
Keypad or user interface failure
Applies to
4 Roper models on 1 platform
Can you keep using it?
With caution

What the dryer is detecting

The control watches for a key that stays pressed and checks that the interface belongs with the control.

Causes listed for this condition

In the order the service documentation checks them. Documented causes come from the manufacturer's service documentation for these platforms; possible causes are based on how the system works; unconfirmed marks common assumptions that the documentation does not support.

  1. Documented A stuck button or failed keypad.
  2. Documented A user interface that does not match the main control.

Safe checks you can make

  • Press each button and check that it springs back; clean around the keys with a barely damp cloth.
  • Turn the dryer off at the breaker (or unplug it) for about one minute, restore power and start a new cycle to see whether the code comes back right away.

Further diagnosis requires opening the appliance. Beyond the owner checks, diagnosis involves removing panels, testing components and checking wiring. We describe what a technician investigates, not how to do it yourself.

What a technician checks

  • Runs the keypad test in the diagnostic mode.
  • Verifies the interface part number.

Typical repairs and cost

Depending on what diagnosis finds, this code can lead to one of these repairs:

RepairTypical rangeLabor
Dryer user interface / keypad replacement$230–$510Light

Typical total ranges for the Las Vegas area, parts and labor included. The final cost depends on diagnosis, the exact model, parts availability and whether other damage is found.

Can you keep using it?

Use with caution. The dryer can usually be used, but a stuck key may cause erratic operation.

Roper models documented with this code

Other codes documented on the same Roper platforms:

Repair or replace?

A fault code alone rarely justifies replacing a dryer. Most F02 repairs involve a single component once diagnosed. Replacement becomes worth considering when the unit is near the end of its typical 12–14-year life and the diagnosed repair is a major one. See the repair-or-replace guide.

Need F02 diagnosed in the Las Vegas area?

We repair Whirlpool, Maytag, KitchenAid, JennAir, Amana and other Whirlpool-family appliances in Las Vegas, Henderson, Summerlin and Boulder City. A model number helps but is never required to book.