CodeMeaningApplianceBrand pages
F1E1Main control fault
F1E1 means the dryer's main control has detected a problem with itself or with one of the relays it uses to switch the motor and heat.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley, Inglis
F1E1Motor or heater circuit failure
F1E1 on 2019 and newer platforms means the main control found a problem in the motor circuit or the heat circuit, or did not detect power where it expected it at the…
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Inglis
F1E1Motor, compressor or heater circuit failure
F1E1 on heat pump dryers means the control did not detect power where expected at the heater, compressor or motor relay, or found a connector problem in one of those…
Heat-pump dryerWhirlpool
F1E1-1Heater circuit fault
F1E1-1 on 2024 platforms means the main control found the heat circuit open or shorted.
Electric dryer, Gas dryerWhirlpool, Admiral
F1E1-3Motor circuit fault
F1E1-3 on 2024 platforms means the main control found the drive motor circuit open or shorted.
Electric dryer, Gas dryerWhirlpool, Admiral
F1E3Incorrect controller installed
F1E3 means the main control or user interface installed in the dryer does not match the model, usually after a board was replaced with the wrong part.
Electric dryer, Gas dryerWhirlpool, Maytag
F2E1Stuck button or interface problem
F2E1 means the control panel reports a button held down continuously (about 20 seconds or more) or, on older platforms, a user interface that does not match the control.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Crosley
F2E2User interface software error
F2E2 on 2008-2011 platforms means the user interface board could not read its own stored software.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F2E2User interface internal fault
F2E2 on 2020 and newer platforms means the user interface (control panel) board has detected a fault inside itself.
Electric dryer, Gas dryerWhirlpool, Maytag, Crosley
F2E3Control programming error
F2E3 on 2010 platforms means the main control's stored model programming was not loaded correctly.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F2E3Interface and control mismatch
F2E3 on 2015-2016 platforms means the user interface and the main control carry different model settings, usually after a board was replaced with the wrong part.
Electric dryer, Gas dryerWhirlpool, Maytag
F3E1Exhaust thermistor fault
F3E1 means the main control is getting an impossible reading from the exhaust (outlet air) temperature sensor, usually an open circuit and, on newer models, either open…
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Crosley, Inglis
F3E1Exhaust thermistor fault
F3E1 on heat pump dryers means the exhaust air temperature sensor reads as open or shorted.
Heat-pump dryerWhirlpool
F3E2Exhaust thermistor shorted
F3E2 on older platforms means the exhaust (outlet air) temperature sensor reads as shorted, a value that would mean an implausibly high temperature.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley, Inglis
F3E2Moisture sensor fault
F3E2 on 2013 and newer platforms means the moisture sensor strip in the drum reads as open or shorted.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley, Inglis
F3E2Moisture sensor fault
F3E2 on heat pump dryers means the moisture sensor strip reads as open or shorted. It appears only in the service diagnostic mode.
Heat-pump dryerWhirlpool
F3E3Inlet thermistor fault
F3E3 means the inlet temperature sensor at the heat source reads as open, and on 2020 and newer platforms either open or shorted.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Crosley
F3E4Inlet thermistor shorted
F3E4 means the inlet temperature sensor at the heat source reads as shorted, which would correspond to a temperature far beyond normal.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F3E4Compressor thermistor fault
F3E4 on heat pump dryers means the compressor temperature sensor reads as open or shorted.
Heat-pump dryerWhirlpool
F3E5Second (rear) moisture sensor fault
F3E5 on 2019 and newer platforms means the second moisture sensor, fitted only to models with a dual (rear) sensor, reads as open or shorted.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F3E5Inlet and exhaust thermistors open
F3E5 on 2008-2017 platforms means both the inlet and the exhaust temperature sensors read as open at the same time.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F3E5Compressor and outlet thermistors open
F3E5 on the 2014-2015 hybrid heat pump platforms means the compressor and outlet temperature sensors both read as open.
Electric dryer, Gas dryerWhirlpool
F3E6Moisture sensor open
F3E6 means the moisture sensor strip circuit reads as open. It is shown only in the service diagnostic menu.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F3E7Moisture sensor shorted
F3E7 means a moisture sensor strip circuit reads as shorted, or on some 2015-2016 dual-sensor models that the rear sensor is open or shorted. It is a service-menu code.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F3E8Compressor sensor open
F3E8 on 2014-2015 hybrid heat pump models means the compressor temperature sensor reads as open. The documentation says this code stops the dryer.
Electric dryer, Gas dryerWhirlpool
F3E9Compressor sensor shorted
F3E9 on 2014-2015 hybrid heat pump models means the compressor temperature sensor reads as shorted. The documentation says this code stops the dryer.
Electric dryer, Gas dryerWhirlpool
F4E1Heat circuit or connector problem
F4E1 means the main control switched on the heat but did not detect power through the heat relay circuit, pointing to a heater, connector or relay problem.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F4E2Second heater circuit problem
F4E2 on 2015-2016 electric models means the control did not detect power through the second heater relay circuit.
Electric dryer, Gas dryerWhirlpool, Maytag
F4E3Restricted airflow
F4E3 means the dryer has detected low airflow through the drum and vent, which hurts drying performance and makes the dryer run hotter.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F4E4L2 line voltage error
F4E4 means the control detected that one side (L2) of the 240-volt power supply is missing or very low on electric models. On gas models the documentation points to an…
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
F4E5High limit (overheating)
F4E5 on 2015-2016 platforms means the dryer exceeded its maximum allowed temperature. The documentation ties this to poor airflow.
Electric dryer, Gas dryerWhirlpool, Maytag
F6E1Communication error (control and interface)
F6E1 means the main control and the user interface (the control panel board) have stopped hearing each other for longer than the control allows.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Crosley
F6E1Communication error (control and interface)
F6E1 on heat pump dryers means communication between the main control and the user interface board has not been detected.
Heat-pump dryerWhirlpool
F6E2Communication error (control to interface)
F6E2 means communication between the main control and the user interface board has been lost, reported from the opposite side of the link from F6E1.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Admiral, Crosley
F6E2Communication error (control and interface)
F6E2 on heat pump dryers means communication between the main control and the user interface board has not been detected.
Heat-pump dryerWhirlpool
F6E3Communication error (control cannot hear interface)
F6E3 on 2013-2016 platforms means the main control is not receiving messages from the user interface board.
Electric dryer, Gas dryerWhirlpool, Maytag
F7E1Motor system fault
F7E1 on 2025 and newer platforms means the control detected a fault in the drive motor system.
Electric dryer, Gas dryerWhirlpool, Maytag
F8E1Water valve failure (steam models)
F8E1 on 2006 steam dryers means the control did not detect power at the water valve relay used for steam. It appears only in the service diagnostic mode.
Electric dryer, Gas dryerWhirlpool, Maytag
F9E1Condensate drain system error
F9E1 on 2014-2015 hybrid heat pump models means the condensate collection area stayed full while the dryer ran, so water is not being pumped away.
Electric dryer, Gas dryerWhirlpool
F9E2Drain assembly failure
F9E2 on heat pump dryers means the condensate float stayed in the full position for more than about a minute while the pump was running, so collected water is not being…
Heat-pump dryerWhirlpool
F01Primary control failure
F01 (F-01) means the dryer's main electronic control has reported an internal failure.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F02Keypad or user interface failure
F02 (F-02) means a control panel button appears stuck or the user interface does not match the control. It appears only in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F20Heater 1 failure
F20 (F-20) on this 2016 electric platform means the control detected a failure in the first heater circuit.
Electric dryer, Gas dryerWhirlpool, Amana, Crosley
F22Exhaust thermistor open
F22 (F-22) on 2005-2016 platforms means the exhaust air temperature sensor reads as open.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F23Exhaust thermistor shorted
F23 (F-23) on 2005-2016 platforms means the exhaust air temperature sensor reads as shorted.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F24Inlet thermistor open
F24 (F-24) means the inlet temperature sensor at the heat source reads as open. It appears only in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F25Inlet thermistor shorted
F25 (F-25) means the inlet temperature sensor at the heat source reads as shorted. It appears only in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F26Motor drive system failure
F26 (F-26) means the control detected a failure in the motor drive system, the circuit that turns the drum and blower.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F28Moisture sensor open
F28 (F-28) means the moisture sensor strip circuit reads as open. It appears only in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F29Moisture sensor shorted
F29 (F-29) means the moisture sensor strip circuit reads as shorted. It appears only in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
F30Restricted airflow condition
F30 (F-30) on 2006-2007 models means the dryer detected a restricted airflow condition. It is shown in the diagnostic test mode.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Roper, Admiral, Crosley
AFRestricted airflow
AF means the dryer has detected low airflow, either during a cycle or, on some 2007-2011 models, during the airflow check run at installation.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
L2Low line voltage
L2 means the dryer detected low or missing voltage on the second leg (L2) of its 240-volt power supply.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
PFPower failure
PF means power to the dryer was interrupted while a cycle was running. It is a notice, not a fault.
Electric dryer, Gas dryerWhirlpool, Maytag, Amana, Crosley
PFPower failure
PF means power to the dryer was interrupted while a cycle was running. It is a notice, not a fault.
Heat-pump dryerWhirlpool